Description
Instrument dimensions
Footprint 610 mm × 250 mm (W × D)
Height 430 mm
Weight (without accessories) 10 kg
Interfaces
PC USB 3.0
Environment
Operating temperature 10 to 40 °C
Humidity without condensation
Power supply
Voltage 88 to 264 V
Power consumption 40 W
Frequency 50 to 60 Hz
Housing and peripherals
Levelling yes
Sample dimensions
Maximum sample space 320 mm × ∞ × 165 mm (W × D × H (without axes))
Temperature control
Equipment Optional:
– temperature-controlled sample stage
– chamber
– cuvette
Type of temperature control liquid
liquid (large)
Peltier
electrical
Range of temperature control liquid: 5 to 90 °C
liquid (large): -10 to 130 °C
Peltier: -30 to 160 °C
electrical: 50 to 400 °C
Maximum sample space 132 mm × 132 mm × 27 mm (W × D × H)
(Large liquid chamber)
Resolution 0.1 °C
Flow-through thermostat with liquid
Inert gas yes
Temperature measurement
Range -50 to 400 °C
Resolution 0.1 °C
Precision ±0.1 °C
Accuracy 1/3 DIN B (±0.1 °C at 0 °C to ±0.8 °C at 400 °C)
Locations sample stage
chamber
cuvette
External sensor retrofittable
Sessile drop
Results contact angle
Range 0 to 180° (software-based)
Resolution 0.01° (software-based)
Accuracy 0.1° (instrument-based)
Models conic section
polynomial
circle
Young-Laplace
height-width
Type static
dynamic
tilting
Software
Software type ADVANCE
Software modules Contact angle (recommended)
Surface free energy of solids (optional)
Interfacial and surface tension of liquids:
– pendant drop, rising drop (optional)
– Contrained Sessile Drop (optional)
Adhesion Analysis (optional)
Remote Control API (optional)
Fiber contact angle:
– Meniscus (optional)
Surface free energy of solids
Results surface free energy
polar & disperse part
acid & base part
H-bond part
Models equation of state
Zisman
Fowkes
Wu
Owens-Wendt-Rabel-Kaelble
Schultz-1
extended Fowkes
acid-base theory
Pendant drop/rising drop
Results surface tension
interfacial tension
Range 0.01 to 2000 mN/m (software-based)
Resolution 0.01 mN/m (software-based)
Models Young-Laplace
Type static
dynamic
Captive bubble
Results contact angle
Range 0 to 180° (software-based)
Resolution 0.01° (software-based)
Accuracy 0.1° (instrument-based)
Models conic section
polynomial
circle
Young-Laplace
height-width
Type static
dynamic
tilting
Dosing System
Syringe Dosing 1 × manual
Liquid Needle double pressure dosing optional
Drop deposition (syringe dosing) manual
Syringes, volume glass (500 μL), disposable (1 mL)
Resolution (syringe dosing) –
Speed (syringe dosing) –
Camera system (standard)
Model Camera CF04
Connection USB 3.0
Resolution 1920 × 1200 px
Frame rate 2300 fps
Dark noise 7 electrons
Dynamic range 73 dB
Optics (standard)
Focus manual
Zoom 6.5× zoom, manual
View angle ±3°
Field of view CF04: 3.2 mm × 3.2 mm to 18.5 mm × 18.5 mm
Resolution of optics CF04: 2.5 to 16.2 μm
Illumination
Type high power monochromatic LED
Wave length, dominant 470 nm
Field of light Ø 42 mm
Stages
Control z-axis: manual (movable in x- and y-direction)
Length z-axis: 45 mm
Optics (optional)
Focus manual
Zoom 6.5× zoom, manual
View angle ±3°
Field of view CF10: 7.1 mm × 5.6 mm to 49.8 mm × 39.4 mm
Resolution of optics CF10: 2.7 to 19.2 μm
Tilting (optional)
Types external tilting table
Control software-controlled
Range 0 to 90°
Resolution 0.01°
Accuracy 0.5°
Liquid Needle pressure dosing system
Included in setup optional
Type double
Control software-controlled
Cartridge, volume disposable (1 mL)
Resolution 0.1 μL
Speed fixed (fast jet)
Camera system (optional)
Model 5 megapixel high speed camera CF10
Connection USB 3.0
Resolution 2592 × 2048 px
Frame rate 3450 fps
Dark noise 9.3 electrons
Dynamic range 60 dB
Reviews